Industrial HVLS fans are common ventilation equipment in industrial production, playing an important role in providing comfortable working environments, reducing energy consumption, and enhancing air circulation. To ensure long-term stable operation and extend service life, routine maintenance is crucial.

I. Daily Inspection (Weekly)

  • Listen: For abnormal noises, periodic friction sounds during operation;
  • Look: For deformed, cracked, or dusty fan blades; check if anti-fall steel cables are loose;
  • Record: Operating current and noise changes for comparison with abnormalities.

II. Quarterly Maintenance

After power-off, check torque of fasteners (flange bolts, blade bolts, anti-fall pins); clean dust from fan blades and guards; check gearbox oil level and leakage; test temperature of inverter and control terminal blocks.

III. Annual Major Maintenance

Performed by manufacturer's professional team: motor insulation testing, bearing condition detection, dynamic balance calibration, comprehensive inspection of safety components (steel cables, fall arresters) with report. Guangding provides 1-2 free inspections annually for clients.

IV. Precautions

Strictly prohibit any maintenance during fan operation; before rainy season, inspect roof leakage impact on the motor; for long-term shutdown, power off and run at low speed for 10 minutes monthly to maintain lubrication.